System details

Type
Service Penetration
Element
Wall
Substrate
Double Layer
Minimum Substrate Thickness
100 mm
FRL / FRR
-/120/90
Trade
Plumbing / Hydraulic / Active Fire
Service
Plastic Pipes, UPVC
Fire Rating
120

Fire-stopping products

BF-3085-2 system drawing

Application dimensions

Min Diameter
0 mm
Max Diameter
110 mm
Service Diameter Range
Up to 110 mm
Aperture
156 x 110 mm
Annular Gap
Fill area around pipe mm
Sealant Depth
10 mm

Specimen size & details

Up to 110 mm uPVC pipe with 6.6 mm wall thickness. The pipe was installed at a 30° angle to the separating element through a 156 mm x 110 mm aperture. Sealant installed around service 10 mm deep in annular gap finished flush both sides. The system includes a 160 mm BOSS MaxiCollar™ installed to both sides.